Injecting Auto-instrumentation
The OpenTelemetry Operator supports injecting and configuring auto-instrumentation libraries for .NET, Java, Node.js, Python, and Go services.
Installation
First, install the OpenTelemetry Operator into your cluster.
You can do this with the Operator release manifest, the Operator helm chart, or with Operator Hub.
In most cases, you will need to install cert-manager. If you use the helm chart, there is an option to generate a self-signed cert instead.
If you want to use Go auto-instrumentation, you need to enable the feature gate. See Controlling Instrumentation Capabilities for details.
Create an OpenTelemetry Collector (Optional)
It is a best practice to send telemetry from containers to an OpenTelemetry Collector instead of directly to a backend. The Collector helps simplify secret management, decouples data export problems (such as a need to do retries) from your apps, and lets you add additional data to your telemetry, such as with the k8sattributesprocessor component. If you chose not to use a Collector, you can skip to the next section.
The Operator provides a Custom Resource Definition (CRD) for the OpenTelemetry Collector which is used to create an instance of the Collector that the Operator manages. The following example deploys the Collector as a deployment (the default), but there are other deployment modes that can be used.
When using the Deployment
mode the operator will also create a Service that
can be used to interact with the Collector. The name of the service is the name
of the OpenTelemetryCollector
resource prepended to -collector
. For our
example that will be demo-collector
.
kubectl apply -f - <<EOF
apiVersion: opentelemetry.io/v1alpha1
kind: OpenTelemetryCollector
metadata:
name: demo
spec:
config: |
receivers:
otlp:
protocols:
grpc:
endpoint: 0.0.0.0:4317
http:
endpoint: 0.0.0.0:4318
processors:
memory_limiter:
check_interval: 1s
limit_percentage: 75
spike_limit_percentage: 15
batch:
send_batch_size: 10000
timeout: 10s
exporters:
# NOTE: Prior to v0.86.0 use `logging` instead of `debug`.
debug:
service:
pipelines:
traces:
receivers: [otlp]
processors: [memory_limiter, batch]
exporters: [debug]
metrics:
receivers: [otlp]
processors: [memory_limiter, batch]
exporters: [debug]
logs:
receivers: [otlp]
processors: [memory_limiter, batch]
exporters: [debug]
EOF
The above command results in a deployment of the Collector that you can use as an endpoint for auto-instrumentation in your pods.
Configure Automatic Instrumentation
To be able to manage automatic instrumentation, the Operator needs to be configured to know what pods to instrument and which automatic instrumentation to use for those pods. This is done via the Instrumentation CRD.
Creating the Instrumentation resource correctly is paramount to getting auto-instrumentation working. Making sure all endpoints and env vars are correct is required for auto-instrumentation to work properly.
.NET
The following command will create a basic Instrumentation resource that is configured specifically for instrumenting .NET services.
kubectl apply -f - <<EOF
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
metadata:
name: demo-instrumentation
spec:
exporter:
endpoint: http://demo-collector:4318
propagators:
- tracecontext
- baggage
sampler:
type: parentbased_traceidratio
argument: "1"
EOF
By default, the Instrumentation resource that auto-instruments .NET services
uses otlp
with the http/protobuf
protocol. This means that the configured
endpoint must be able to receive OTLP over http/protobuf
. Therefore, the
example uses http://demo-collector:4318
, which will connect to the http
port
of the otlpreceiver
of the Collector created in the previous step.
Excluding auto-instrumentation
By default, the .NET auto-instrumentation ships with
many instrumentation libraries.
This makes instrumentation easy, but could result in too much or unwanted data.
If there are any libraries you do not want to use you can set the
OTEL_DOTNET_AUTO_[SIGNAL]_[NAME]_INSTRUMENTATION_ENABLED=false
where
[SIGNAL]
is the type of the signal and [NAME]
is the case-sensitive name of
the library.
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
metadata:
name: demo-instrumentation
spec:
exporter:
endpoint: http://demo-collector:4318
propagators:
- tracecontext
- baggage
sampler:
type: parentbased_traceidratio
argument: '1'
dotnet:
env:
- name: OTEL_DOTNET_AUTO_TRACES_GRPCNETCLIENT_INSTRUMENTATION_ENABLED
value: false
- name: OTEL_DOTNET_AUTO_METRICS_PROCESS_INSTRUMENTATION_ENABLED
value: false
Learn more
For more details, see .NET Auto Instrumentation docs.
Java
The following command creates a basic Instrumentation resource that is configured for instrumenting Java services.
kubectl apply -f - <<EOF
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
metadata:
name: demo-instrumentation
spec:
exporter:
endpoint: http://demo-collector:4318
propagators:
- tracecontext
- baggage
sampler:
type: parentbased_traceidratio
argument: "1"
EOF
By default, the Instrumentation resource that auto-instruments Java services
uses otlp
with the http/protobuf
protocol. This means that the configured
endpoint must be able to receive OTLP over http
via protobuf
payloads.
Therefore, the example uses http://demo-collector:4318
, which connects to the
http
port of the otlpreceiver of the Collector created in the previous step.
Excluding auto-instrumentation
By default, the Java auto-instrumentation ships with
many instrumentation libraries.
This makes instrumentation easy, but could result in too much or unwanted data.
If there are any libraries you do not want to use you can set the
OTEL_INSTRUMENTATION_[NAME]_ENABLED=false
where [NAME]
is the name of the
library. If you know exactly which libraries you want to use, you can disable
the default libraries by setting
OTEL_INSTRUMENTATION_COMMON_DEFAULT_ENABLED=false
and then use
OTEL_INSTRUMENTATION_[NAME]_ENABLED=true
where [NAME]
is the name of the
library. For more details, see
Suppressing specific instrumentation.
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
metadata:
name: demo-instrumentation
spec:
exporter:
endpoint: http://demo-collector:4318
propagators:
- tracecontext
- baggage
sampler:
type: parentbased_traceidratio
argument: '1'
java:
env:
- name: OTEL_INSTRUMENTATION_KAFKA_ENABLED
value: false
- name: OTEL_INSTRUMENTATION_REDISCALA_ENABLED
value: false
Learn more
For more details, see Java agent Configuration.
Node.js
The following command creates a basic Instrumentation resource that is configured for instrumenting Node.js services.
kubectl apply -f - <<EOF
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
metadata:
name: demo-instrumentation
spec:
exporter:
endpoint: http://demo-collector:4317
propagators:
- tracecontext
- baggage
sampler:
type: parentbased_traceidratio
argument: "1"
EOF
By default, the Instrumentation resource that auto-instruments Node.js services
uses otlp
with the grpc
protocol. This means that the configured endpoint
must be able to receive OTLP over grpc
. Therefore, the example uses
http://demo-collector:4317
, which connects to the grpc
port of the
otlpreceiver
of the Collector created in the previous step.
Excluding instrumentation libraries
By default, the Node.js zero-code instrumentation has all the instrumentation libraries enabled.
To enable only specific instrumentation libraries you can use the
OTEL_NODE_ENABLED_INSTRUMENTATIONS
environment variable as documented in the
Node.js zero-code instrumentation documentation.
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
# ... other fields skipped from this example
spec:
# ... other fields skipped from this example
nodejs:
env:
- name: OTEL_NODE_ENABLED_INSTRUMENTATIONS
value: http,nestjs-core # comma-separated list of the instrumentation package names without the `@opentelemetry/instrumentation-` prefix.
To keep all default libraries and disable only specific instrumentation
libraries you can use the OTEL_NODE_DISABLED_INSTRUMENTATIONS
environment
variable. For details, see
Excluding instrumentation libraries.
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
# ... other fields skipped from this example
spec:
# ... other fields skipped from this example
nodejs:
env:
- name: OTEL_NODE_DISABLED_INSTRUMENTATIONS
value: fs,grpc # comma-separated list of the instrumentation package names without the `@opentelemetry/instrumentation-` prefix.
Note
If both environment variables are set,OTEL_NODE_ENABLED_INSTRUMENTATIONS
is
applied first, and then OTEL_NODE_DISABLED_INSTRUMENTATIONS
is applied to that
list. Therefore, if the same instrumentation is included in both lists, that
instrumentation will be disabled.Learn more
For more details, see Node.js auto-instrumentation.
Python
The following command will create a basic Instrumentation resource that is configured specifically for instrumenting Python services.
kubectl apply -f - <<EOF
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
metadata:
name: demo-instrumentation
spec:
exporter:
endpoint: http://demo-collector:4318
propagators:
- tracecontext
- baggage
sampler:
type: parentbased_traceidratio
argument: "1"
EOF
By default, the Instrumentation
resource that auto-instruments Python services
uses otlp
with the http/protobuf
protocol (gRPC is not supported at this
time). This means that the configured endpoint must be able to receive OTLP over
http/protobuf
. Therefore, the example uses http://demo-collector:4318
, which
will connect to the http
port of the otlpreceiver
of the Collector created
in the previous step.
As of operator v0.67.0, the Instrumentation resource automatically sets
OTEL_EXPORTER_OTLP_TRACES_PROTOCOL
andOTEL_EXPORTER_OTLP_METRICS_PROTOCOL
tohttp/protobuf
for Python services. If you use an older version of the Operator you MUST set these env variables tohttp/protobuf
, or Python auto-instrumentation will not work.
Auto-instrumenting Python logs
By default, Python logs auto-instrumentation is disabled. If you would like to
enable this feature, you must to set the OTEL_LOGS_EXPORTER
and
OTEL_PYTHON_LOGGING_AUTO_INSTRUMENTATION_ENABLED
environment variables as
follows:
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
metadata:
name: python-instrumentation
namespace: application
spec:
exporter:
endpoint: http://demo-collector:4318
env:
propagators:
- tracecontext
- baggage
python:
env:
- name: OTEL_LOGS_EXPORTER
value: otlp_proto_http
- name: OTEL_PYTHON_LOGGING_AUTO_INSTRUMENTATION_ENABLED
value: 'true'
Note that
OTEL_LOGS_EXPORTER
must be explicitly set tootlp_proto_http
, otherwise it defaults to gRPC.
Excluding auto-instrumentation
By default, the Python auto-instrumentation ships with
many instrumentation libraries.
This makes instrumentation easy, but can result in too much or unwanted data. If
there are any packages you do not want to instrument, you can set the
OTEL_PYTHON_DISABLED_INSTRUMENTATIONS
environment variable.
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
metadata:
name: demo-instrumentation
spec:
exporter:
endpoint: http://demo-collector:4318
propagators:
- tracecontext
- baggage
sampler:
type: parentbased_traceidratio
argument: '1'
python:
env:
- name: OTEL_PYTHON_DISABLED_INSTRUMENTATIONS
value:
<comma-separated list of package names to exclude from
instrumentation>
Learn more
See the Python agent Configuration docs for more details.
Go
The following command creates a basic Instrumentation resource that is configured specifically for instrumenting Go services.
kubectl apply -f - <<EOF
apiVersion: opentelemetry.io/v1alpha1
kind: Instrumentation
metadata:
name: demo-instrumentation
spec:
exporter:
endpoint: http://demo-collector:4318
propagators:
- tracecontext
- baggage
sampler:
type: parentbased_traceidratio
argument: "1"
EOF
By default, the Instrumentation resource that auto-instruments Go services uses
otlp
with the http/protobuf
protocol. This means that the configured
endpoint must be able to receive OTLP over http/protobuf
. Therefore, the
example uses http://demo-collector:4318
, which connects to the http/protobuf
port of the otlpreceiver
of the Collector created in the previous step.
The Go auto-instrumentation does not support disabling any instrumentation. See the Go Auto-Instrumentation repository for more details.
Now that your Instrumentation object is created, your cluster has the ability to auto-instrument services and send data to an endpoint. However, auto-instrumentation with the OpenTelemetry Operator follows an opt-in model. In order to activate automatic instrumentation, you’ll need to add an annotation to your deployment.
Add annotations to existing deployments
The final step is to opt in your services to automatic instrumentation. This is
done by updating your service’s spec.template.metadata.annotations
to include
a language-specific annotation:
- .NET:
instrumentation.opentelemetry.io/inject-dotnet: "true"
- Go:
instrumentation.opentelemetry.io/inject-go: "true"
- Java:
instrumentation.opentelemetry.io/inject-java: "true"
- Node.js:
instrumentation.opentelemetry.io/inject-nodejs: "true"
- Python:
instrumentation.opentelemetry.io/inject-python: "true"
The possible values for the annotation can be
"true"
- to injectInstrumentation
resource with default name from the current namespace."my-instrumentation"
- to injectInstrumentation
CR instance with name"my-instrumentation"
in the current namespace."my-other-namespace/my-instrumentation"
- to injectInstrumentation
CR instance with name"my-instrumentation"
from another namespace"my-other-namespace"
."false"
- do not inject
Alternatively, the annotation can be added to a namespace, which will result in all services in that namespace to opt-in to automatic instrumentation. See the Operators auto-instrumentation documentation for more details.
Opt-in a Go Service
Unlike other languages’ auto-instrumentation, Go works via an eBPF agent running
via a sidecar. When opted in, the Operator will inject this sidecar into your
pod. In addition to the instrumentation.opentelemetry.io/inject-go
annotation
mentioned above, you must also supply a value for the
OTEL_GO_AUTO_TARGET_EXE
environment variable.
You can set this environment variable via the
instrumentation.opentelemetry.io/otel-go-auto-target-exe
annotation.
instrumentation.opentelemetry.io/inject-go: 'true'
instrumentation.opentelemetry.io/otel-go-auto-target-exe: '/path/to/container/executable'
This environment variable can also be set via the Instrumentation resource, with
the annotation taking precedence. Since Go auto-instrumentation requires
OTEL_GO_AUTO_TARGET_EXE
to be set, you must supply a valid executable path via
the annotation or the Instrumentation resource. Failure to set this value causes
instrumentation injection to abort, leaving the original pod unchanged.
Since Go auto-instrumentation uses eBPF, it also requires elevated permissions. When you opt in, the sidecar the Operator injects will require the following permissions:
securityContext:
capabilities:
add:
- SYS_PTRACE
privileged: true
runAsUser: 0
Troubleshooting
If you run into problems trying to auto-instrument your code, here are a few things that you can try.
Did the Instrumentation resource install?
After installing the Instrumentation
resource, verify that it installed
correctly by running this command, where <namespace>
is the namespace in which
the Instrumentation
resource is deployed:
kubectl describe otelinst -n <namespace>
Sample output:
Name: python-instrumentation
Namespace: application
Labels: app.kubernetes.io/managed-by=opentelemetry-operator
Annotations: instrumentation.opentelemetry.io/default-auto-instrumentation-apache-httpd-image:
ghcr.io/open-telemetry/opentelemetry-operator/autoinstrumentation-apache-httpd:1.0.3
instrumentation.opentelemetry.io/default-auto-instrumentation-dotnet-image:
ghcr.io/open-telemetry/opentelemetry-operator/autoinstrumentation-dotnet:0.7.0
instrumentation.opentelemetry.io/default-auto-instrumentation-go-image:
ghcr.io/open-telemetry/opentelemetry-go-instrumentation/autoinstrumentation-go:v0.2.1-alpha
instrumentation.opentelemetry.io/default-auto-instrumentation-java-image:
ghcr.io/open-telemetry/opentelemetry-operator/autoinstrumentation-java:1.26.0
instrumentation.opentelemetry.io/default-auto-instrumentation-nodejs-image:
ghcr.io/open-telemetry/opentelemetry-operator/autoinstrumentation-nodejs:0.40.0
instrumentation.opentelemetry.io/default-auto-instrumentation-python-image:
ghcr.io/open-telemetry/opentelemetry-operator/autoinstrumentation-python:0.39b0
API Version: opentelemetry.io/v1alpha1
Kind: Instrumentation
Metadata:
Creation Timestamp: 2023-07-28T03:42:12Z
Generation: 1
Resource Version: 3385
UID: 646661d5-a8fc-4b64-80b7-8587c9865f53
Spec:
...
Exporter:
Endpoint: http://demo-collector.opentelemetry.svc.cluster.local:4318
...
Propagators:
tracecontext
baggage
Python:
Image: ghcr.io/open-telemetry/opentelemetry-operator/autoinstrumentation-python:0.39b0
Resource Requirements:
Limits:
Cpu: 500m
Memory: 32Mi
Requests:
Cpu: 50m
Memory: 32Mi
Resource:
Sampler:
Events: <none>
Do the OTel Operator logs show any auto-instrumentation errors?
Check the OTel Operator logs for any errors pertaining to auto-instrumentation by running this command:
kubectl logs -l app.kubernetes.io/name=opentelemetry-operator --container manager -n opentelemetry-operator-system --follow
Were the resources deployed in the right order?
Order matters! The Instrumentation
resource needs to be deployed before
deploying the application, otherwise the auto-instrumentation won’t work.
Recall the auto-instrumentation annotation:
annotations:
instrumentation.opentelemetry.io/inject-python: 'true'
The annotation above tells the OTel Operator to look for an Instrumentation
object in the pod’s namespace. It also tells the Operator to inject Python
auto-instrumentation into the pod.
When the pod starts up, the annotation tells the Operator to look for an
Instrumentation object in the pod’s namespace, and to inject
auto-instrumentation into the pod. It adds an
init-container
to the application’s pod, called opentelemetry-auto-instrumentation
, which is
then used to injects the auto-instrumentation into the app container.
If the Instrumentation
resource isn’t present by the time the application is
deployed, however, the init-container can’t be created. Therefore, if the
application is deployed before deploying the Instrumentation
resource, the
auto-instrumentation will fail.
To make sure that the opentelemetry-auto-instrumentation
init-container has
started up correctly (or has even started up at all), run the following command:
kubectl get events -n <your_app_namespace>
Which should output something like this:
53s Normal Created pod/py-otel-server-7f54bf4cbc-p8wmj Created container opentelemetry-auto-instrumentation
53s Normal Started pod/py-otel-server-7f54bf4cbc-p8wmj Started container opentelemetry-auto-instrumentation
If the output is missing Created
and/or Started
entries for
opentelemetry-auto-instrumentation
, then it means that there is an issue with
your auto-instrumentation. This can be the result of any of the following:
- The
Instrumentation
resource wasn’t installed (or wasn’t installed properly). - The
Instrumentation
resource was installed after the application was deployed. - There’s an error in the auto-instrumentation annotation, or the annotation in the wrong spot — see #4 below.
Be sure to check the output of kubectl get events
for any errors, as these
might help point to the issue.
Is the auto-instrumentation annotation correct?
Sometimes auto-instrumentation can fail due to errors in the auto-instrumentation annotation.
Here are a few things to check for:
- Is the auto-instrumentation for the right language? For example, when
instrumenting a Python application, make sure that the annotation doesn’t
incorrectly say
instrumentation.opentelemetry.io/inject-java: "true"
instead. - Is the auto-instrumentation annotation in the correct location? When
defining a
Deployment
, annotations can be added in one of two locations:spec.metadata.annotations
, andspec.template.metadata.annotations
. The auto-instrumentation annotation needs to be added tospec.template.metadata.annotations
, otherwise it won’t work.
Was the auto-instrumentation endpoint configured correctly?
The spec.exporter.endpoint
attribute of the Instrumentation
resource defines
where to send data to. This can be an OTel Collector, or any
OTLP endpoint. If this attribute is left out, it defaults to
http://localhost:4317
, which, most likely won’t send telemetry data anywhere.
When sending telemetry to an OTel Collector located in the same Kubernetes
cluster, spec.exporter.endpoint
should reference the name of the OTel
Collector
Service
.
For example:
spec:
exporter:
endpoint: http://demo-collector.opentelemetry.svc.cluster.local:4317
Here, the Collector endpoint is set to
http://demo-collector.opentelemetry.svc.cluster.local:4317
, where
demo-collector
is the name of the OTel Collector Kubernetes Service
. In the
above example, the Collector is running in a different namespace from the
application, which means that opentelemetry.svc.cluster.local
must be appended
to the Collector’s service name, where opentelemetry
is the namespace in which
the Collector resides.
Feedback
Was this page helpful?
Thank you. Your feedback is appreciated!
Please let us know how we can improve this page. Your feedback is appreciated!